Customization: | Available |
---|---|
Task: | Program |
Structure: | Combination |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Distributed PLC | ||||
GCAN PLC-400 | GCAN PLC-510 | GCAN PLC-511 | ||
Local bus | Ethernet*1 RS232/485*1 CAN*1 | Ethernet*1 RS232/485*1 CAN*1 | Ethernet*1 RS232*1 RS485*1 CAN*2 | |
IO expansion capability | 1024*8 points | 2048*8 points | ||
Modbus TCP | Main site | Support 5 slave stations | Support 10 slave stations | |
Slaves | 5 main site links | 10 main site links | ||
Modbus RTU | Main site | Support 32 slave stations | Support 64 slave stations | |
Slaves | Unrestricted | |||
CANopen | Main site | Support 16 slave stations | Support 32 slave stations | |
Slaves | Node number 1-127 can be set arbitrarily | |||
Program capacity | 512K | 16M | ||
RAM | 256Kbyte | 8Mbyte | ||
special function | CANopen control server Local PLC data moved to the cloud Monitor multiple Ethernet computers simultaneously | |||
programming language | IL LD ST SFC CFC FBD | |||
Support software | CodesysV3.5, OpenPCS V7.1 choose before placing an order | |||
Software license | Authorized before leaving the factory, the programming software is free to use |
GC-1008 | 8 digital inputs PNP | GC-3822 | 2 PT100 inputs (3 lines 16 bits) |
GC-1018 | 8 digital inputs NPN | GC-3832 | 2 PT1000 inputs (3 lines 16 bits) |
GC-1016 | 16 digital inputs PNP | GC-3844 | 4-way K-type thermocouple input |
GC-1502 | 2 counter inputs | GC-3854 | 4-way S-type thermocouple input |
GC-1602 | 2 channels AB phase encoder input | GC-3864 | 4-way T-type thermocouple input |
GC-2008 | 8 digital outputs PNP | GC-3874 | 4-way] type thermocouple input |
GC-2018 | 8 digital outputs NPN | GC-4602 | 2 channels of -5~+5V output (16 bits) |
GC-2016 | 16 digital outputs PNP | GC-4622 | 2 channels of -10~+10V output (16 bits) |
GC-2204 | 4 relay outputs (220V 0.1A/24V 1A) | GC-4642 | 2 channels of 0-20mA output (16 bits) |
GC-2214 | 4 relay outputs (220V 2A/24V 3A) | GC-4652 | 2 channels of 4-20mA output (16 bits |
GC-2302 | 2 PWM outputs | GC-4662 | 2 channels of 0~+5V output (16 bits) |
GC-3604 | 4 channels of -5~+5V input (16 bits) | GC-4672 | 2 channels of 0~+10V output (16 bits) |
GC-3624 | 4 channels of -10~+10V input (16 bits) | GC-4674 | 4 channels of 0~+10V output (12 bits) |
GC-3644 | 4 channels 0-20mA input (16 bits) | GC-4684 | 4 channels of 0~+10V output (16 bits) |
GC-3654 | 4 channels 4-20mA input (16 bits) | GC-6101 | RS232/RS485 extension |
GC-3664 | 4 channels of 0~+5V input (16 bits) | GC-6221 | 4G extension |
GC-3674 | 4 channels of 0~+10V input (16 bits) | GC-6501 | WiFi extension |
GC-3804 | 4 PT100 inputs (2 lines 16 bits) | GC-8012 | power extension |
GC-3814 | 4 PT1000 inputs (2 lines 16 bits | GC-0001 | terminal module |
Product Model | Communication Interface Type | Supported Communication Bus Types | Integrated IO Quantity And Type | Expansion IO Plug Quantity And Type | Programming Software | Programming Language |
PLC-301 | 1*RS232+1*RS485 | Modbus RTU | Digital input IO number*8, digital output IO number*6, counter input IO number*4, counter output IO number*4 | Digital/analog input/output IO, RS232/485 4G WIFI communication module, up to 16 pieces | Codesys OpenPCS | Sequential Function Chart (SFC) Ladder Diagram (LD) Structured Text (ST) Function Block Diagram (FBD) Instruction List(IL) |
PLC-302 | 1*RS232+ 1*RS485+1*CAN | Modbus RTU CANopen | ||||
PLC-320 | 1*RS232+1*RS485+ 2*Ethernet | Modbus RTU/TCP | ||||
PLC-321 | 1*RS232+1*RS485+ 2*Ethernet+1*CAN | Modbus RTU/TCP CANopen | ||||
PLC-322 | 1*RS232+1*RS485+ 2*Ethernet+2*CAN | |||||
PLC-400 | 1*RS232/485+ 1*Ethernet+1*CAN | The main control head itself does not have any IO interface | Digital/analog input/output IO, RS232/485 4G WIFI communication module, up to 32 pieces | |||
PLC-425 | 1*CAN+1*Ethernet+ 1*EtherCAT+ 1*RS485 | Modbus RTU/TCP CANopen EtherCAT | ||||
PLC-430 | 2*CAN+1*Ethernet+ 1*EtherCAT+ 1*RS485+1*RS232 | |||||
PLC-510 | 1*RS232/485+ 1*Ethernet+1*CAN | Modbus RTU/TCP CANopen | ||||
PLC-511 | 1*RS232/485+ 1*Ethernet+2*CAN | |||||
PLC-530 | 2*CAN+1*Ethernet+ 1*Ethernet/EtherCAT +1*RS485+1*RS232 | Modbus RTU/TCP CANopen EtherCAT | ||||
PLC-535 | Digital input IO number*8, digital output IO number*6 |