Customization: | Available |
---|---|
Task: | Program |
Structure: | Combination |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(1) 12-channel source/sink type digital input DI, input voltage 24V DC. The maximum input voltage is 25VDC, and the maximum input current is 5mA (single channel); |
(2) 8-channel transistor PNP digital output DO, output voltage 24V DC. The maximum output current is 3A (single channel); |
(3) 4 analog input AI, 0V~+10V, image bit width 16Bit (0~65535); |
(4) 2 analog output AO, 0V~+10V, image bit width 12Bit (0~4095); |
(5) 2 CAN bus interfaces, 1 Ethernet interface, 2 RS485 interfaces; |
(6) Programming software: OpenPCS (programming language complies with IEC 61131-3 standard); |
(7) The power supply uses 24V DC (-15%/+20%); the maximum input current is 1.5A; |
(8) Electrical isolation is 1500 Vrms; |
(9) Operating temperature range: -40℃~+85℃; |
(10) Protection level: IP20; |
Product Model | Communication Interface Type | Supported Communication Bus Types | Integrated IO Quantity And Type | Expansion IO Plug Quantity And Type | Programming Software | Programming Language |
PLC-301 | 1*RS232+1*RS485 | Modbus RTU | Digital input IO number*8, digital output IO number*6, counter input IO number*4, counter output IO number*4 | Digital/analog input/output IO, RS232/485 4G WIFI communication module, up to 16 pieces | Codesys OpenPCS | Sequential Function Chart (SFC) Ladder Diagram (LD) Structured Text (ST) Function Block Diagram (FBD) Instruction List(IL) |
PLC-302 | 1*RS232+ 1*RS485+1*CAN | Modbus RTU CANopen | ||||
PLC-320 | 1*RS232+1*RS485+ 2*Ethernet | Modbus RTU/TCP | ||||
PLC-321 | 1*RS232+1*RS485+ 2*Ethernet+1*CAN | Modbus RTU/TCP CANopen | ||||
PLC-322 | 1*RS232+1*RS485+ 2*Ethernet+2*CAN | |||||
PLC-400 | 1*RS232/485+ 1*Ethernet+1*CAN | The main control head itself does not have any IO interface | Digital/analog input/output IO, RS232/485 4G WIFI communication module, up to 32 pieces | |||
PLC-425 | 1*CAN+1*Ethernet+ 1*EtherCAT+ 1*RS485 | Modbus RTU/TCP CANopen EtherCAT | ||||
PLC-430 | 2*CAN+1*Ethernet+ 1*EtherCAT+ 1*RS485+1*RS232 | |||||
PLC-510 | 1*RS232/485+ 1*Ethernet+1*CAN | Modbus RTU/TCP CANopen | ||||
PLC-511 | 1*RS232/485+ 1*Ethernet+2*CAN | |||||
PLC-530 | 2*CAN+1*Ethernet+ 1*Ethernet/EtherCAT +1*RS485+1*RS232 | Modbus RTU/TCP CANopen EtherCAT | ||||
PLC-535 | Digital input IO number*8, digital output IO number*6 |