Gcan-204 RS485 Serial Industrial Grade Modbus RTU Protocol to Can Bus Gateway Converter Terminal Wiring DIN Rail Installation

Still deciding? Get samples of $ !
Order Sample
Product Details
Customization: Available
Usage: Computer, Workstation, Server, Laptop, Can Bus
Type: Wired
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 15 days
OEM Services
The supplier provides OEM services for popular brands
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (18)
  • Gcan-204 RS485 Serial Industrial Grade Modbus RTU Protocol to Can Bus Gateway Converter Terminal Wiring DIN Rail Installation
  • Gcan-204 RS485 Serial Industrial Grade Modbus RTU Protocol to Can Bus Gateway Converter Terminal Wiring DIN Rail Installation
  • Gcan-204 RS485 Serial Industrial Grade Modbus RTU Protocol to Can Bus Gateway Converter Terminal Wiring DIN Rail Installation
  • Gcan-204 RS485 Serial Industrial Grade Modbus RTU Protocol to Can Bus Gateway Converter Terminal Wiring DIN Rail Installation
  • Gcan-204 RS485 Serial Industrial Grade Modbus RTU Protocol to Can Bus Gateway Converter Terminal Wiring DIN Rail Installation
  • Gcan-204 RS485 Serial Industrial Grade Modbus RTU Protocol to Can Bus Gateway Converter Terminal Wiring DIN Rail Installation
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Application
  • Packing
  • Factory & Certification
  • FAQ
Overview

Basic Info.

Model NO.
GCAN-204 Modbus RTU to CAN Converter
Support Network
Ethernet
Certification
CE, ISO, RoHS
Condition
New
Product Name
Modbus RTU to Can Converter
Product Model
Gcan-204
Product Interface
Power Supply*1+Can*1+RS485*1
Standard Serial Port
2-Wire RS485 Interface
Serial Port Baud Rate
600BPS~115200BPS
Can Bus Baud Rate
5kbps~1mbpa
Isolation Method
Can Bus Interface Electrical Isolation
Insulation Voltage
DC 1500V
Supply Voltage
9-24V DC
Wiring Method
Terminal Wiring
Installation Method
DIN Rail
Operating Temperature
-40℃~+85℃
Transport Package
Carton
Specification
112*100*22mm
Trademark
GCAN/OEM
Origin
China
HS Code
8517629990
Production Capacity
500000/Year

Packaging & Delivery

Package Size
20.00cm * 16.00cm * 6.00cm
Package Gross Weight
0.500kg
Lead Time
25 days (1 - 200 Pieces)
45 days (201 - 500 Pieces)
To be negotiated ( > 500 Pieces)

Product Description

Product Description
GCAN-204 MODBUS RTU to CAN Gateway
GCAN-204 module is an industrial-grade Modbus RTU to CAN module that integrates 1 standard serial port and 1 standard CAN bus interface. The GCAN-204 module serial bus terminal has integrated the Modbus RTU protocol. Using the GCAN-204 module, users can use the device that originally used the serial bus for communication (Modbus RTU protocol) to obtain the CAN bus communication interface without changing the original hardware structure, so that the device that uses the Modbus RTU protocol for communication can be quickly connected to the CAN bus to form a node in the CAN bus network.
GCAN-204 module reads data on the Modbus, it will load the data received on the CAN bus into the cache in real time and wait for the Modbus command to read. After receiving the Modbus read command, the module will convert the specified CAN data and send it to the Modbus bus; when the module receives the Modbus send data command, it will directly process the Modbus data and send it to the CAN bus. The GCAN-204 module is a key tool for industrial bus transformation and interconnection of multiple bus devices. At the same time, the module has the characteristics of small size and plug-and-play, and is also the best choice for existing system integration. Various bus interfaces of GCAN-204 are integrated with isolation protection modules to prevent damage to the module due to instantaneous overvoltage and overcurrent. The use of DIN rail fixing method makes it easier to integrate into various control cabinets.
Gcan-204 RS485 Serial Industrial Grade Modbus RTU Protocol to Can Bus Gateway Converter Terminal Wiring DIN Rail Installation
Specification
Hardware feature
High-speed 32-bit processor
Embedded hardware watchdog timer
Power supply voltage: DC 24V
Maximum current: 40mA
Electrostatic discharge immunity level: contact discharge ± 2KV, air discharge ±15KV
Surge immunity level: ± 1KV
Operating temperature range: -40 ℃ ~ +85 ℃
Operating humidity range: 5% to 95% RH 
Electrical fast transient burst immunity level: ± 1KV
CAN feature
Integrated 1 CAN-Bus interface with terminal
CAN-Bus signals : CAN_H, CAN_L, CAN_GND
CAN-Bus supports CAN2.0A and CAN2.0B frame format, conform to ISO/DIS11898 standards
CAN-Bus baud rates range from 5Kbps to 1Mbps
CAN-Bus isolation converter insulation voltage: DC 1500V
Ethernet feature
RJ45, support 10 / 100M adaptive
Modbus slave support function code: 03H, 04H, 06H, 16H
Support static or dynamic IP access
Support heartbeat and timeout interrupt function
The working port is fixed, the target IP and the target port can be set
After the network is disconnected, the connection resource is automatically restored and the TCP connection is established reliably
Support protocols include EtherNET, ARP, IP, ICMP, UDP, DHCP, DNS, TCP
Compatible with SOCKET work (TCP Server, TCP Client, UDP, etc.), the host computer communication software follows the standard SOCKET rules
Gcan-204 RS485 Serial Industrial Grade Modbus RTU Protocol to Can Bus Gateway Converter Terminal Wiring DIN Rail Installation
Gcan-204 RS485 Serial Industrial Grade Modbus RTU Protocol to Can Bus Gateway Converter Terminal Wiring DIN Rail Installation
Application
Gcan-204 RS485 Serial Industrial Grade Modbus RTU Protocol to Can Bus Gateway Converter Terminal Wiring DIN Rail Installation
Gcan-204 RS485 Serial Industrial Grade Modbus RTU Protocol to Can Bus Gateway Converter Terminal Wiring DIN Rail Installation
Packing
NOTE:
The product software is not mailed with the package, we will send the software link to you by email or other contact methods to ensure your smooth use!
Gcan-204 RS485 Serial Industrial Grade Modbus RTU Protocol to Can Bus Gateway Converter Terminal Wiring DIN Rail Installation
Factory & Certification
Gcan-204 RS485 Serial Industrial Grade Modbus RTU Protocol to Can Bus Gateway Converter Terminal Wiring DIN Rail Installation
FAQ
1. who are we?
We are based in Liaoning, China, start from 2010, sell to Domestic Market(70.00%). Southeast Asia(12.00%).South America(5.00%),Mid East(5. 00). Northern Europe(3. 00), Southern Europe(3.00%),Africa(2.00%).    There are total about 1150 people in our office

2. how can we guarantee quality?
Always a pre-production sample before mass production,Always final Inspection before shipment.

3. what can you buy from us?
Controller, Data Analyzer, Converter

4. why should you buy from us not from other suppliers?
Our company has more 20 own intellectual-property rights with all of main products by ourselves, which is a leading supplier and service provider of industrial interconnection equipment in the country.

5. what services can we provide?
Accepted Delivery Terms: FOB, DDP,Express Delivery;
Accepted Payment Currency: USD, CNY;
Accepted Payment Type: T/T, Westem Union, Money Gram, Alipay, Paypal. Cash;
Language Spoken: English, Chinese

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now